VPL Power-Limiting Heating Cable

Raychem VPL power-limiting trace heating cables are mainly used for process temperature maintenance applications that require steam cleaning, up to 455 °F/235 °C and withstand intermittent exposure to 500 °F/260 °C. VPL offers high power output at high temperatures, which can reduce the number of heating cables required and is hazardous area approved. Also suitable for freeze protection. The fluoropolymer outer jacket (-CT) provides high chemical resistance against aggressive organics and corrosives.

Features

  • Efficient system design: high power output at elevated temperatures reduces heating cable required, flat P-T curve results in lower T start up and power equipment costs, longer circuit lengths due to larger cross section conductors
  • Maximum circuit length further increases when operating at higher voltages: reducing the number of circuits and power supply equipment
  • Fast installation: cut-to-length, multiple overlaps allowed, meter markings, user-friendly connections kits
  • Safe and efficient in operation: no overheating, uniform pipe temperatures, energy saving technology
  • Reliable during long life: 10 year product warranty available, maintenance free

Specifications

Area Classification: Non-Hazardous; Hazardous

Ground Path Type: Braid

Max Continuous Exposure Temperature, Power Off: 260 °C

Max Cumulative Hours for Intermittent Exposure: 1000 h

Min Installation Temperature: -60 °C

Outer Jacket Material: High Temperature Fluoropolymer

Supply Voltage: 400 – 480 V

Catalog NumberItem NameMax Maintain or Continuous Exposure Temperature, Power OnNominal Power Output @ 10°C, 230VNominal Power Output @ 10°C, 240VNominal Power Output @ 10°C, 400V
068380-00015VPL2-CT230 °C45 W/m49 W/m
451828-0005VPL2-CT235 °C15 W/m16 W/m
589252-00020VPL2-CT150 °C61 W/m65 W/m
892652-00010VPL2-CT220 °C30 W/m33 W/m
P0000006785VPL4-CT230 °C12 W/m
P00000067910VPL4-CT205 °C24 W/m
P00000068015VPL4-CT170 °C36 W/m
P00000068120VPL4-CT150 °C49 W/m

Download

DatasheetRAYCHEM-DS-H56825-VPL-EN
Installation ManualRAYCHEM-IM-H57274-SelfRegPowerLimHeatTrac-EN
Design GuideRaychem-DG-H56882-SelfRegulating-EN

Engineering Inquiry: Heating Cable Design & Selection

Please provide me with the following information:
  • Country Name?
  • Plant Name?
  • Ambient Minimum Temperature?
  • Process Liquid?
  • Process Temperature?
  • Maintain Temperature?
  • Design Temperature?
  • Insulation Material?
  • Insulation Thickness?
  • Voltage?
Scroll to Top